Specifications
Electrical parameters
Light source | LED |
Power voltage | AC 220–240 V / 50–60 Hz |
Connection method | leading out cable, leading out cable with connector (G) disconnect terminal block (O), without cable (WO) |
Ballast part | electronic driver with surge protection L/N-Ground 10 kV |
Surge protection | additional surge protection 10 kV (S) |
Fuse | fuse 6,3 A (J) |
Possibility of regulation | non-dimmable (not labeled), DALI (DALI), night dimming (A) preparation for wireless communication NEMA (N), Zhaga (Z) or 2× Zhaga (Z2) |
Sensor | motion sensor (on request) |
Constant lumen output | CLO (C) |
Light parameters
Optical system | roads (Mxx), roads (Lxx), directional (Pxx), area (Uxx), pedastrian crossing (ZLx/ZPx) combined optics (Kxx), BACK light shades (BL1/BL2), FRONT light shades (FL1/FL2) |
Light distribution | direct |
Colour rendering index | Ra > 70, Ra > 80 |
Colour temperature | BLUE FREE (AMBER) / 2,200 K / 2,700 K / 3,000 K / 4,000 K / 5,000 K / 5 700k /TW |
Service life | > 100 000 hrs. (L90B10) |
Construction
Luminaire body | aluminum cast |
Colour | RAL 7015/9006 |
Surface type | matte |
Luminaire cover | tempered glass |
Safety
Protection class | I, II |
Maximum ambient temperature | -40 / 55 °C |
Ingress proection | IP 66 |
Impact protection | IK 09 |
EMC | YES |
Vibration test | YES |
Corrosion test | YES |
Certification | ENEC, ENEC+, Zhaga-D4i, IDA Dark Sky Approved, IDA Dark sky approved |
RoHS | YES |
REACH | YES |
Mounting
Method | pole or boom mounted (48–60 mm); 60–76 mm (on request) adjustable joint ± 15° |
Recommended height | max. up to 8 m |
Additional equipment | external aperture CPZ - on order |
Use | bike path, outdoor areas, pedestrian zones, sidewalks; road classes I., II. and III. |
Variants
Luminaire ambient temperature TQ 25 °C,
Initial color consistency: ≤ 5 SDCM.
Optical and electrical parameters tolerance ± 10 %.
IDA Dark Sky fixture seal of approval relates to ≤ 3 000 K
To meet IDA requirements, the luminaires must be installed horizontally with the road
When using the CLO function, the initial power and luminous flux
is 10 % lower than the value shown in the table. LDT curves with
CLO function have the letter “C” at the end of their marking.
The term BLUE FREE (AMBER) in lighting technology refers to light with a minimum amount of the blue part of the light spectrum (< 2%).